AFCH-90DB Series
■ Feature
● AC Input:176~264VAC/200~370VDC
● According with Safety-Standard design
● With UPS function
● Very wide working temperature (-25℃~
● Protection:Overload/Short/Over voltage
● Battery under-voltage protection, auto-recovery after battery changed
● All capacitor used high working temperature
● 2 year warranty
■SPEC
Model | AFCH-90D12+13.8B | AFCH-90D18+21B | AFCH-90D24+27.6B | AFCH-90D30+27.6B | |||||
Output | Output Voltage | V1:12V | BAT:13.8V | V1:18V | BAT:21V | V1:24V | BAT:27.6V | V1:30V | BAT:27.6V |
Rated Current(convention) | 6.0A | 0.5A | 4.0A | 0.5A | 3.0A | 0.5A | 2.5A | 0.5A | |
(0.4~0.65A) | (0.4~0.6A) | (0.4~0.6A) | (0.4~0.6A) | ||||||
Rated Output Power | 78.9W | 80.5W | 85.8W | 88.8W | |||||
Ripple & Noise | <120 mV | / | <120 mV | / | <120 mV | / | <120 mV | / | |
DC adjustment range | 12.0~13.8V | / | 17.0-19.0V | / | 28.5-31.5V | / | 28.5-31.5V | / | |
Output Voltage Tolerence | ±3.0% | / | ±3.0% | / | ±3.0% | / | ±3.0% | / | |
Setup time | ≤1S (230Vac input, Full load) | ||||||||
Hold up time | ≥25mS(230Vac input, Full load) | ||||||||
Output Inrush | <5.0% | ||||||||
Dynamic | 10%-100%Load:10%Vp-p 10%-50%Load: 5%Vp-p 50%-100%Load: 5%Vp-p | ||||||||
Input | Input Voltage range | 176Vac~264Vac | |||||||
Rated Input Voltage | 200Vac~240Vac/47Hz~63Hz | ||||||||
Start-up Voltage | 176Vac | ||||||||
Efficient (Type) | 80% | 80% | 81% | 82% | |||||
Input Current(Max) | <1.5A | ||||||||
Start-up Inrush Current | <40A@230Vac Cold start |